提交 c422cddb authored 作者: Michael Jerris's avatar Michael Jerris

FS-8946: [mod_xml_cdr] fix segfault on call after loading with no config file or…

FS-8946: [mod_xml_cdr] fix segfault on call after loading with no config file or event bind failure causing module load failure
上级 da91717b
......@@ -502,6 +502,7 @@ SWITCH_MODULE_LOAD_FUNCTION(mod_xml_cdr_load)
if (switch_event_bind_removable(modname, SWITCH_EVENT_TRAP, SWITCH_EVENT_SUBCLASS_ANY, event_handler, NULL, &globals.node) != SWITCH_STATUS_SUCCESS) {
switch_log_printf(SWITCH_CHANNEL_LOG, SWITCH_LOG_ERROR, "Couldn't bind!\n");
switch_core_remove_state_handler(&state_handlers);
return SWITCH_STATUS_GENERR;
}
......@@ -517,6 +518,9 @@ SWITCH_MODULE_LOAD_FUNCTION(mod_xml_cdr_load)
/* parse the config */
if (!(xml = switch_xml_open_cfg(cf, &cfg, NULL))) {
switch_log_printf(SWITCH_CHANNEL_LOG, SWITCH_LOG_ERROR, "Open of %s failed\n", cf);
switch_event_unbind(&globals.node);
switch_core_remove_state_handler(&state_handlers);
switch_thread_rwlock_destroy(globals.log_path_lock);
return SWITCH_STATUS_FALSE;
}
......
Markdown 格式